Abutment angular Warantec D Ø4.0, H 28, angle of inclination 15°, IUAA1528HA
Angular abutment Warantec D Ø4.0, H 28, inclination angle 15°, IUAA1528HA
- Abutment for the production of structures with cement or cement-screw fixation
- Complete set: Abutment + titanium screw
- Impression from the implant level
- Connection with a 1.2 hex screwdriver
- Compensates for the implant inclination angle from 15° to 25°
- Possibility of use in complex clinical situations
- Recommended fixation method: 10 minutes after fixation, tighten again with a force of 30 Ncm
- Recommended force: 30 Ncm
Abutment angular Warantec D Ø5.0, H 36, angle of inclination 20°, IUAA20 36H
Angular abutment Warantec D Ø5.0, H 36, inclination angle 20°, IUAA20 36H
- Abutment for the production of structures with cement or cement-screw fixation
- Complete set: Abutment + titanium screw
- Impression from the implant level
- Connection with a 1.2 hex screwdriver
- Compensates for the implant inclination angle from 15° to 25°
- Possibility of use in complex clinical situations
- Recommended fixation method: 10 minutes after fixation, tighten again with a force of 30 Ncm
- Recommended force: 30 Ncm
Abutment angular Warantec D Ø5.0, H 66, angle of inclination 15°, IUAA1566H
Angular abutment Warantec D Ø5.0, H 66, inclination angle 15°, IUAA1566H
- Abutment for the production of structures with cement or cement-screw fixation
- Complete set: Abutment + titanium screw
- Impression from the implant level
- Connection with a 1.2 hex screwdriver
- Compensates for the implant inclination angle from 15° to 25°
- Possibility of use in complex clinical situations
- Recommended fixation method: 10 minutes after fixation, tighten again with a force of 30 Ncm
- Recommended force: 30 Ncm
Abutment double Warantec Ø3.95 IUSB40 15H
Warantec Double Abutment Ø3.95 IUSB40 15H
- Abutment for manufacturing structures with cement or cement-screw fixation
- Impression from the implant level
- Connection with a 1.2 hex screwdriver
- Recommended force: 30 Ncm.
- Recommended fixation method: 10 minutes after fixation, tighten again with a force of 30 Ncm.
- Complete set: abutment + titanium screw
Abutment double Warantec Ø3.95 IUSB40 15HA
Warantec Double Abutment Ø3.95 IUSB40 15HA
- Abutment for manufacturing structures with cement or cement-screw fixation
- Impression from the implant level
- Connection with a 1.2 hex screwdriver
- Recommended force: 30 Ncm.
- Recommended fixation method: 10 minutes after fixation, tighten again with a force of 30 Ncm.
- Complete set: abutment + titanium screw
Abutment double Warantec Ø3.95 IUSB40 15N
Warantec Double Abutment Ø3.95 IUSB40 15N
- Abutment for manufacturing structures with cement or cement-screw fixation
- Impression from the implant level
- Connection with a 1.2 hex screwdriver
- Recommended force: 30 Ncm.
- Recommended fixation method: 10 minutes after fixation, tighten again with a force of 30 Ncm.
- Complete set: abutment + titanium screw
Abutment double Warantec Ø3.95 IUSB40 15NA
Warantec Double Abutment Ø3.95 IUSB40 15NA
- Abutment for manufacturing structures with cement or cement-screw fixation
- Impression from the implant level
- Connection with a 1.2 hex screwdriver
- Recommended force: 30 Ncm.
- Recommended fixation method: 10 minutes after fixation, tighten again with a force of 30 Ncm.
- Complete set: abutment + titanium screw
Abutment double Warantec Ø3.95 IUSB40 17H
Warantec Double Abutment Ø3.95 IUSB40 17H
- Abutment for manufacturing structures with cement or cement-screw fixation
- Impression from the implant level
- Connection with a 1.2 hex screwdriver
- Recommended force: 30 Ncm.
- Recommended fixation method: 10 minutes after fixation, tighten again with a force of 30 Ncm.
- Complete set: abutment + titanium screw
Abutment double Warantec Ø3.95 IUSB40 17HA
Warantec Double Abutment Ø3.95 IUSB40 17HA
- Abutment for manufacturing structures with cement or cement-screw fixation
- Impression from the implant level
- Connection with a 1.2 hex screwdriver
- Recommended force: 30 Ncm.
- Recommended fixation method: 10 minutes after fixation, tighten again with a force of 30 Ncm.
- Complete set: abutment + titanium screw
Abutment double Warantec Ø3.95 IUSB40 17N
Warantec Double Abutment Ø3.95 IUSB40 17N
- Abutment for manufacturing structures with cement or cement-screw fixation
- Impression from the implant level
- Connection with a 1.2 hex screwdriver
- Recommended force: 30 Ncm.
- Recommended fixation method: 10 minutes after fixation, tighten again with a force of 30 Ncm.
- Complete set: abutment + titanium screw
Abutment double Warantec Ø3.95 IUSB40 17NA
Warantec Double Abutment Ø3.95 IUSB40 17NA
- Abutment for manufacturing structures with cement or cement-screw fixation
- Impression from the implant level
- Connection with a 1.2 hex screwdriver
- Recommended force: 30 Ncm.
- Recommended fixation method: 10 minutes after fixation, tighten again with a force of 30 Ncm.
- Complete set: abutment + titanium screw
Abutment double Warantec Ø3.95 IUSB40 25HA
Warantec Double Abutment Ø3.95 IUSB40 25HA
- Abutment for manufacturing structures with cement or cement-screw fixation
- Impression from the implant level
- Connection with a 1.2 hex screwdriver
- Recommended force: 30 Ncm.
- Recommended fixation method: 10 minutes after fixation, tighten again with a force of 30 Ncm.
- Complete set: abutment + titanium screw