Showing 61–72 of 203 results

Abutment double Warantec Ø4.95 IUSB50 37N

CHF 45.00
Warantec Double Abutment Ø4.95 IUSB50 37N
  • Abutment for manufacturing structures with cement or cement-screw fixation
  • Impression from the implant level
  • Connection with a 1.2 hex screwdriver
  • Recommended force: 30 Ncm.
  • Recommended fixation method: 10 minutes after fixation, tighten again with a force of 30 Ncm.
  • Complete set: abutment + titanium screw

Abutment double Warantec Ø4.95 IUSB504 5H

CHF 45.00
Warantec Double Abutment Ø4.95 IUSB504 5H
  • Abutment for manufacturing structures with cement or cement-screw fixation
  • Impression from the implant level
  • Connection with a 1.2 hex screwdriver
  • Recommended force: 30 Ncm.
  • Recommended fixation method: 10 minutes after fixation, tighten again with a force of 30 Ncm.
  • Complete set: abutment + titanium screw

Abutment double Warantec Ø4.95 IUSB504 5N

CHF 45.00
Warantec Double Abutment Ø4.95 IUSB504 5N
  • Abutment for manufacturing structures with cement or cement-screw fixation
  • Impression from the implant level
  • Connection with a 1.2 hex screwdriver
  • Recommended force: 30 Ncm.
  • Recommended fixation method: 10 minutes after fixation, tighten again with a force of 30 Ncm.
  • Complete set: abutment + titanium screw

Abutment double Warantec Ø4.95 IUSB504 7H

CHF 45.00
Warantec Double Abutment Ø4.95 IUSB504 7H
  • Abutment for manufacturing structures with cement or cement-screw fixation
  • Impression from the implant level
  • Connection with a 1.2 hex screwdriver
  • Recommended force: 30 Ncm.
  • Recommended fixation method: 10 minutes after fixation, tighten again with a force of 30 Ncm.
  • Complete set: abutment + titanium screw

Abutment double Warantec Ø4.95 IUSB504 7N

CHF 45.00
Warantec Double Abutment Ø4.95 IUSB504 7N
  • Abutment for manufacturing structures with cement or cement-screw fixation
  • Impression from the implant level
  • Connection with a 1.2 hex screwdriver
  • Recommended force: 30 Ncm.
  • Recommended fixation method: 10 minutes after fixation, tighten again with a force of 30 Ncm.
  • Complete set: abutment + titanium screw

Abutment double Warantec Ø4.95 IUSB505 5H

CHF 45.00
Warantec Double Abutment Ø4.95 IUSB505 5H
  • Abutment for manufacturing structures with cement or cement-screw fixation
  • Impression from the implant level
  • Connection with a 1.2 hex screwdriver
  • Recommended force: 30 Ncm.
  • Recommended fixation method: 10 minutes after fixation, tighten again with a force of 30 Ncm.
  • Complete set: abutment + titanium screw

Abutment double Warantec Ø4.95 IUSB505 5N

CHF 45.00
Warantec Double Abutment Ø4.95 IUSB505 5N
  • Abutment for manufacturing structures with cement or cement-screw fixation
  • Impression from the implant level
  • Connection with a 1.2 hex screwdriver
  • Recommended force: 30 Ncm.
  • Recommended fixation method: 10 minutes after fixation, tighten again with a force of 30 Ncm.
  • Complete set: abutment + titanium screw

Abutment double Warantec Ø4.95 IUSB505 7H

CHF 45.00
Warantec Double Abutment Ø4.95 IUSB505 7H
  • Abutment for manufacturing structures with cement or cement-screw fixation
  • Impression from the implant level
  • Connection with a 1.2 hex screwdriver
  • Recommended force: 30 Ncm.
  • Recommended fixation method: 10 minutes after fixation, tighten again with a force of 30 Ncm.
  • Complete set: abutment + titanium screw

Abutment double Warantec Ø4.95 IUSB505 7N

CHF 45.00
Warantec Double Abutment Ø4.95 IUSB505 7N
  • Abutment for manufacturing structures with cement or cement-screw fixation
  • Impression from the implant level
  • Connection with a 1.2 hex screwdriver
  • Recommended force: 30 Ncm.
  • Recommended fixation method: 10 minutes after fixation, tighten again with a force of 30 Ncm.
  • Complete set: abutment + titanium screw

Abutment double Warantec Ø4.95 IUSB506 5H

CHF 45.00
Warantec Double Abutment Ø4.95 IUSB506 5H
  • Abutment for manufacturing structures with cement or cement-screw fixation
  • Impression from the implant level
  • Connection with a 1.2 hex screwdriver
  • Recommended force: 30 Ncm.
  • Recommended fixation method: 10 minutes after fixation, tighten again with a force of 30 Ncm.
  • Complete set: abutment + titanium screw

Abutment double Warantec Ø4.95 IUSB506 5N

CHF 45.00
Warantec Double Abutment Ø4.95 IUSB506 5N
  • Abutment for manufacturing structures with cement or cement-screw fixation
  • Impression from the implant level
  • Connection with a 1.2 hex screwdriver
  • Recommended force: 30 Ncm.
  • Recommended fixation method: 10 minutes after fixation, tighten again with a force of 30 Ncm.
  • Complete set: abutment + titanium screw

Abutment double Warantec Ø4.95 IUSB506 7H

CHF 45.00
Warantec Double Abutment Ø4.95 IUSB506 7H
  • Abutment for manufacturing structures with cement or cement-screw fixation
  • Impression from the implant level
  • Connection with a 1.2 hex screwdriver
  • Recommended force: 30 Ncm.
  • Recommended fixation method: 10 minutes after fixation, tighten again with a force of 30 Ncm.
  • Complete set: abutment + titanium screw